Verilink HDM 2180
User Manual
October 1999
P/N 880-503048-001-F
PRI
EXT
MANAGEMENT
HDM
2180
NET
DATA
SYS
LOCAL
SNMP
Przeglądanie stron 0
1 2 3 4 5 6 ... 78 79

Podsumowanie treści

Strona 1 - User Manual

Verilink HDM 2180 User ManualOctober 1999P/N 880-503048-001-FPRIEXTMANAGEMENTHDM2180NETDATASYSLOCALSNMP

Strona 2 - FCC Requirements

x Verilink HDM 2180 User Manual

Strona 3 - Lithium Battery

Verilink HDM 2180 User Manual 1-1Chapter1HDM 2180 DS3 DSU OverviewThis manual describes how to use the HDM 2180 DS3 DSU Craft interface. As part of Ve

Strona 4 - Safety Precautions

HDM 2180 DS3 DSU Overview1-2 Verilink HDM 2180 User ManualLocal ASCIIInterface PortThe Local port provides the Craft interface for configuration, cont

Strona 5 - Publications Staff

HDM 2180 DS3 DSU OverviewVerilink HDM 2180 User Manual 1-3Far-End Alarm and ControlDedicated support is provided for Far End Alarm and Control (FEAC)

Strona 6 - Verilink HDM 2180 User Manual

HDM 2180 DS3 DSU Overview1-4 Verilink HDM 2180 User ManualFigure 1-2 HDM 2180 Front Panel Figure 1-3 CDM 2080 Rear Panel Figure 1-4 Functional Block

Strona 7 - Table of Contents

HDM 2180 DS3 DSU OverviewVerilink HDM 2180 User Manual 1-5Table 1-2 Data Port SpecificationsTable 1-3 Environmental SpecificationsRegulatory Requireme

Strona 8 - 6: Troubleshooting

HDM 2180 DS3 DSU Overview1-6 Verilink HDM 2180 User Manual•15.812: Conducted Emission•UL 1459, 2nd Edition•CSA—C225TechnicalReferences forNetwork Inte

Strona 9

HDM 2180 DS3 DSU OverviewVerilink HDM 2180 User Manual 1-7FCC ComplianceFor the HDM 2180 to comply with FCC Part 15, ferrites must be placed on the fo

Strona 10

HDM 2180 DS3 DSU Overview1-8 Verilink HDM 2180 User ManualFigure 1-6 Terminal Block One on the MLS—Chassis Ground Connected to Signal GroundFigure 1-7

Strona 11 - HDM 2180 DS3 DSU Overview

Verilink HDM 2180 User Manual 2-1Chapter2HDM 2180 Quick Set-UpThis chapter provides step-by-step procedures for setting up your HDM 2180 module. This

Strona 12 - SNMP Port

iiVerilink HDM 2180 User ManualCopyright NoticeCopyright  1999 Verilink Corporation. All rights reserved.This document does not create any express or

Strona 13 - Technical Description

HDM 2180 Quick Set-Up2-2 Verilink HDM 2180 User ManualNOTE: The node controller module (NCM 2000) is usually installed in slot 1 of shelf 1. However,

Strona 14 - HDM 2180 Specifications

HDM 2180 Quick Set-UpVerilink HDM 2180 User Manual 2-3Figure 2-2 NCM Main Menu From the NCM Craft interface Main Menu (Figure 2-2), select the HDM app

Strona 15 - Regulatory

HDM 2180 Quick Set-Up2-4 Verilink HDM 2180 User ManualFigure 2-3 Configuration Menu Network PortThe DS3 network port is usually configured before the

Strona 16 - Limitations

HDM 2180 Quick Set-UpVerilink HDM 2180 User Manual 2-5HSSI Port Set-up1. Hook up the DTE (in this case, a router) to the HSSI port.2. Type “H” to disp

Strona 17 - BNC Timing Cable

HDM 2180 Quick Set-Up2-6 Verilink HDM 2180 User Manual

Strona 18 - Remove cover

Verilink HDM 2180 User Manual 3-1Chapter3Standalone HDM 2180 ManagementThis chapter describes the Craft interface menu options for a standalone HDM 21

Strona 19 - HDM 2180 Quick Set-Up

Standalone HDM 2180 Management3-2 Verilink HDM 2180 User ManualFigure 3-1 ASCII Screen: Main Menu via HDM 2180 Local PortTable 3-1 HDM 2180 Craft Inte

Strona 20 - Logging On

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-3Although Table 3-1 above presents application management options in the order as they a

Strona 21 - Port Configuration

Standalone HDM 2180 Management3-4 Verilink HDM 2180 User ManualTable 3-2 HDM 2180 Node Administration OptionsCommand DescriptionA Node Address—Use thi

Strona 22 - Network Port

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-5Port Configuration MenuOnce you have established and set the HDM 2180’s IP addresses an

Strona 23 - HSSI Port Set-up

Verilink HDM 2180 User Manualiii • If the telephone company alters its equipment in a manner that can affect the use of this device, it must give you

Strona 24

Standalone HDM 2180 Management3-6 Verilink HDM 2180 User ManualFrom the HDM Craft Interface Menu (Main Menu) choose C to display the Port Configuratio

Strona 25 - Using the Local Port

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-7Table 3-4 DS3 Port Configuration Submenu OptionsCommand DescriptionS DS3 Port Performan

Strona 26 - Module Status

Standalone HDM 2180 Management3-8 Verilink HDM 2180 User ManualE DS3 Port Equipment ID—An optional field in which to describe the type of DTE used. Di

Strona 27 - Administration Menu

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-9HSSI Port ConfigurationFrom the Port Configuration Menu, select H for the HSSI Port op

Strona 28

Standalone HDM 2180 Management3-10 Verilink HDM 2180 User ManualPort Diagnostics Menu and SubmenusThe Port Diagnostics Menu allows limited diagnostics

Strona 29 - Port Configuration Menu

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-11Loopbacks/ DiagnosticsBy returning transmitted signals to their source for comparison,

Strona 30 - Configuration

Standalone HDM 2180 Management3-12 Verilink HDM 2180 User ManualTable 3-7 Port Loopback Diagnostics Menu CommandsTransmitting Diagnostics AlarmsTo ver

Strona 31

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-13Figure 3-8 Transmit Alarms Diagnostics Menu Table 3-8 Transmit Alarms Diagnostics Men

Strona 32 - Figure 3-3

Standalone HDM 2180 Management3-14 Verilink HDM 2180 User ManualPerformance Monitoring MenuPressing P from the Main Menu displays the Performance Moni

Strona 33 - HSSI Port

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-15Figure 3-9 Performance Monitoring Menu Table 3-9 Performance Monitoring Menu Command

Strona 34 - Submenus

ivVerilink HDM 2180 User ManualDeutschVORSICHT!Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs und gleicher Qualität

Strona 35 - Diagnostics

Standalone HDM 2180 Management3-16 Verilink HDM 2180 User ManualFigure 3-10 DS3 NE Performance Monitoring Menu To display the data for any of the para

Strona 36 - Transmitting

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-17Performance DataDisplaysFor example, to see the 24 hr NE LCV Performance Data:HDM >

Strona 37

Standalone HDM 2180 Management3-18 Verilink HDM 2180 User ManualDS3 Layer LocalFar-EndPerformanceMonitoringSubmenuA subset of the far-end 24-hour perf

Strona 38 - Performance Monitoring Menu

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-19Restore Manufacturing Default Config MenuTo restore the manufacturing defaults for the

Strona 39 - Monitoring Menu

Standalone HDM 2180 Management3-20 Verilink HDM 2180 User ManualAlarm MonitoringTo see real-time, continuous alarm notifications, from the Main Menu,

Strona 40

Standalone HDM 2180 ManagementVerilink HDM 2180 User Manual 3-21Alarm BufferTo see a historical listing of alarms, type A from the Main Menu to displa

Strona 41 - Displays

Standalone HDM 2180 Management3-22 Verilink HDM 2180 User Manual

Strona 42 - Submenu (24 Hr

Verilink HDM 2180 User Manual 4-1Chapter4HDM 2180 Management: Using NCM 2000ASCII Access SettingsTo access an HDM 2180 on the node from an ASCII termi

Strona 43

HDM 2180 Management: Using NCM 20004-2 Verilink HDM 2180 User Manual• The letter surrounded by brackets ( [ ] ) designates the location of the curren

Strona 44 - Monitoring

HDM 2180 Management: Using NCM 2000Verilink HDM 2180 User Manual 4-3Using an NCM in your DS3 network offers several advantages:• Higher security on th

Strona 45 - Alarm Buffer

Verilink HDM 2180 User Manualv • This product should be operated only from the type of power source indicated on the marking label and manual. If you

Strona 46

HDM 2180 Management: Using NCM 20004-4 Verilink HDM 2180 User ManualTable 4-2 Shelf and Slot Parameters HDM 2180 Card AdministrationOnce the shelf/slo

Strona 47 - ASCII Access Settings

HDM 2180 Management: Using NCM 2000Verilink HDM 2180 User Manual 4-5Table 4-3 Card Administration Menu Commands Configuration MenuTyping the command C

Strona 48 - Command List

HDM 2180 Management: Using NCM 20004-6 Verilink HDM 2180 User ManualPort Configuration Menu (DS3)From the Configuration Menu, pressing P for the DS3 P

Strona 49 - Shelf and Slot Parameters

HDM 2180 Management: Using NCM 2000Verilink HDM 2180 User Manual 4-7HSSI Port Configuration MenuSelecting H from the Configuration Menu displays the

Strona 50 - HDM 2180 Card Administration

HDM 2180 Management: Using NCM 20004-8 Verilink HDM 2180 User ManualTable 4-6 HSSI Configuration Menu Commands Remote End SetupSelecting R from the

Strona 51 - Configuration Menu

HDM 2180 Management: Using NCM 2000Verilink HDM 2180 User Manual 4-9remote DS3 units, you will be required to manually enter the information under the

Strona 52 - Menu (DS3)

HDM 2180 Management: Using NCM 20004-10 Verilink HDM 2180 User ManualDiagnostics MenuSelecting D from the Main Menu displays the Diagnostics Menu, whi

Strona 53

HDM 2180 Management: Using NCM 2000Verilink HDM 2180 User Manual 4-11Figure 4-9DS3 Port Status ReportSelecting P from the Diagnostics Menu displays th

Strona 54 - Remote End Setup

HDM 2180 Management: Using NCM 20004-12 Verilink HDM 2180 User ManualTable 4-9 HDM 2180 Loopback Options Menu Commands Command DescriptionA Activate

Strona 55

HDM 2180 Management: Using NCM 2000Verilink HDM 2180 User Manual 4-13HDM Transmit Alarm OptionsSelecting T from the Diagnostics Menu displays the HDM

Strona 56 - Diagnostics Menu

viVerilink HDM 2180 User Manual

Strona 57 - Options Menu

HDM 2180 Management: Using NCM 20004-14 Verilink HDM 2180 User ManualTable 4-10 HDM Transmit Alarm Options CommandsPerformance / Status MenuSelecting

Strona 58

HDM 2180 Management: Using NCM 2000Verilink HDM 2180 User Manual 4-15Performance Threshold Setting Option MenuSelecting T) Threshold Setting from the

Strona 59 - Alarm Options

HDM 2180 Management: Using NCM 20004-16 Verilink HDM 2180 User ManualFigure 4-17 HDM 2180 24 Hour Threshold Selector Menu Performance Report Options

Strona 60 - Performance / Status Menu

HDM 2180 Management: Using NCM 2000Verilink HDM 2180 User Manual 4-17Figure 4-19 Alarm Menu Figure 4-20 Sample Alarm Buffer Display Far End DS3 Port

Strona 61 - Setting Option

HDM 2180 Management: Using NCM 20004-18 Verilink HDM 2180 User ManualFigure 4-21 Far End Port Identification Information Display Manufacturing InfoTy

Strona 62 - Alarm Menu

Verilink HDM 2180 User Manual 5-1Chapter5Standalone HDM 2180 SNMP Management NOTE: Before using SNMP, Telnet, FTP, or other TCP/IP protocol, you must

Strona 63

Standalone HDM 2180 SNMP Management5-2 Verilink HDM 2180 User ManualEmbedded Network Management System Using SNMPThe SNMP port connects to an Ethernet

Strona 64 - Manufacturing Info

Standalone HDM 2180 SNMP ManagementVerilink HDM 2180 User Manual 5-3• HDM 2180 uses SNMPv1 community strings.• HDM 2180 provides filtering of SNMPv1 P

Strona 65 - Management

Standalone HDM 2180 SNMP Management5-4 Verilink HDM 2180 User Manual

Strona 66

Verilink HDM 2180 User Manual 6-1Chapter6TroubleshootingWhat Elicits an AlarmThe NCM 2000 module polls the HDM 2180 modules for alarms.If alarm report

Strona 67 - Specifications

HDM 2180Table of ContentsVerilink HDM 2180 User Manual vii1: HDM 2180 DS3 DSU Overview...

Strona 68

Troubleshooting6-2 Verilink HDM 2180 User ManualAlarm DescriptionThe Alarm Description column lists the text that is• printed on the display• sent to

Strona 69 - Troubleshooting

TroubleshootingVerilink HDM 2180 User Manual 6-3• If you have a Powerup Self-test Fail, reseat the module to see if it will power up and pass the self

Strona 70 - What To Do About Alarms

Troubleshooting6-4 Verilink HDM 2180 User Manualdeclared, the HDM 2180 module sends a message to the Craft interface and Node Manager (if used), light

Strona 71 - Interpreting Alarms

TroubleshootingVerilink HDM 2180 User Manual 6-5• C-bit Errored Second (CES)—A CES is a second with one or more CCVs or one or more Out of Frame (OOF)

Strona 72 - Minor Alarms

Troubleshooting6-6 Verilink HDM 2180 User ManualFront Panel LEDsFigure 6-1 HDM 2180 Front Panel LED IndicatorsHDM 2180 provides three tri-color LEDs

Strona 73

TroubleshootingVerilink HDM 2180 User Manual 6-7LCV line code violationsLES Line errored secondsLOFS Loss of frame secondLOSS Loss of signal secondLSE

Strona 74 - Performance Statistics

Troubleshooting6-8 Verilink HDM 2180 User ManualFar-End AlarmsThe following far-end alarms are detected and reported:FEBE Far end block errorFEAC DS3

Strona 75 - Alarm Parameters

HDM 2180IndexVerilink HDM 2180 User Manual Index-1Aadministration submenu 4-4AISS 6-3, 6-5AISS (Alarm Indication Signal Second) 6-3, 6-5alarm buffer

Strona 76 - Far-End Alarms

Index-2 Verilink HDM 2180 User Manualparameters 4-6major alarms 6-3management host IP address 3-4management information base (MIB) 5-2management trap

Strona 77

VERILINK CORPORATION127 JETPLEX CIRCLE, MADISON, ALABAMA 35758TEL: (800) 837-4546October 1999P/N 880-503048-001-F

Strona 78

viii Verilink HDM 2180 User ManualDS3 Layer Performance Alert Thresholds Submenu (24 Hr. NE)... 3-18Restore Manufacturing D

Strona 79

Verilink HDM 2180 User Manual ixLED Indicators.........................