HDM 2182 Quick Set-Up
2-6 Verilink HDM 2182 User Manual
Enter an identifying character string (no more than 18
characters) to specify the Circuit ID. “Port B” is suggested.
5. Type “R”, then E
NTER
, to display the prompt:
Warning: Config NE only. FE rate could become inconsistent.
Change (Y/N)
Type “Y”, then choose the data rate you will be using for your
particular equipment. Choose the number of T1s to be used on
this port (the bandwidth will automatically be calculated and
displayed). The total number of T1s on the HDM module
cannot exceed 28, so for this particular set-up, type “14” for
this port. (Since you already chose 14 for Port A, you will be
limited to 14 for Port B.)
6. Type “X” to exit to the Configuration Menu.
Your HDM 2182 is now configured and ready to be placed into
service by connecting the unit to the appropriate cables to the
network and to your equipment.
The four tri-color LEDs on the front panel (Network Port, Data Ports,
System) should be lit solid green to indicate the module is properly
configured and the equipment is operating normally.