Verilink DPRI 2922User ManualSeptember 1999P/N 880-503142-001A1DPRI2922LOCALSYSMANAGEMENTPRIEXT✳✳✳✳✳NETDATA1212
BACK HOME GLOSSARY INDEXviii Verilink DPRI 2922 PRI Call Profile Configuration Menu ... 3-19Port
Verilink DPRI 2922 1-1ChapterBACK HOME GLOSSARY INDEX1DPRI 2922 Dual-Port ISDN Primary Rate InterfaceThe DPRI 2922 application module working in conju
DPRI 2922 Dual-Port ISDN Primary Rate InterfaceBACK HOME GLOSSARY INDEX1-2 Verilink DPRI 2922FeaturesThe DPRI 2922 system has the following features:T
BACK HOME GLOSSARY INDEXDPRI 2922 Dual-Port ISDN Primary Rate In-Verilink DPRI 2922 1-3Node ManagementThe NCM provides node management via Craft inter
DPRI 2922 Dual-Port ISDN Primary Rate InterfaceBACK HOME GLOSSARY INDEX1-4 Verilink DPRI 2922•Two for data port statusChapter 4 of this manual defines
BACK HOME GLOSSARY INDEXDPRI 2922 Dual-Port ISDN Primary Rate In-Verilink DPRI 2922 1-5Figure 1-3 T1 CIM Configurations NOTE: Data Ports 1 and 2 requ
DPRI 2922 Dual-Port ISDN Primary Rate InterfaceBACK HOME GLOSSARY INDEX1-6 Verilink DPRI 2922Table 1-2 CIM Specifications Technical and Regulatory Co
Verilink DPRI 29222-1Chapter2Quick Set-UpThis chapter provides step-by-step procedures as an example for setting up your DIDCSU 2912 module.NOTE: Sin
Quick Set-Up2-2Verilink DPRI 2922Bus CompatibilityIf there is no indication of the DIDCSU on the “shelf map” on the NCM Main Menu, the modules may be
Quick Set-UpVerilink DPRI 29222-3Figure 2-1 NCM Main Menu -- VERILINK NCM CONTROLLER : FW Rev 4.15, Dec 13 1997 12:53:30 -- Site Name: Verilink
iiVerilink DPRI 2922 User ManualCopyright NoticeCopyright 1999 Verilink Corporation. All rights reserved.This document does not create any express o
Quick Set-Up2-4Verilink DPRI 2922Network Port ConfigurationNOTE: Configure the network ports first, then the data ports.1. From the NCM ASCII interfa
Quick Set-UpVerilink DPRI 29222-56. Press L, then 1, ENTER, then 2 to select B8ZS as the line coding for Net Port 1. Press L, then 2, ENTER, then 2 t
Quick Set-Up2-6Verilink DPRI 2922Figure 2-4 Configuration Menu (FDL Options)2. Press S, then 1, ENTER, to assign the FDL Standard to Network Port 1.
Quick Set-UpVerilink DPRI 29222-7Figure 2-5 Configuration Menu (Timing Options)2. All primary and dial-backup circuits must use shelf timing to sync
Quick Set-Up2-8Verilink DPRI 2922Figure 2-7 Data Port Configuration Menu 3. In the Data Port Configuration Menu, press the letter I, then the numeral
Quick Set-UpVerilink DPRI 29222-911. Press SM, then 1, ENTER, to select the TM for Data Port 1. Press SM, then 2, ENTER, to select the TM for Data Po
Quick Set-Up2-10Verilink DPRI 29222. Set the Switch Type, Own Numbering Plan, and Own Numbering Type according to the parameters your NSP has provide
Quick Set-UpVerilink DPRI 29222-11Figure 2-10 Net Port Alarm Threshold Configuration Menu4. Enable Net Ports 1 and 2 Alarm Reporting (NET) by setting
Quick Set-Up2-12Verilink DPRI 2922Figure 2-11 Circuit Manager MenuWhen this menu is activated for the first time, and no circuits have been built yet
Quick Set-UpVerilink DPRI 29222-13Figure 2-14 Add Circuit MenuFigure 2-15 Circuit Manager Menu•Build T1 to T1 or Data Port to T1 circuits as the prim
Verilink DPRI 2922 User Manualiii • If the telephone company alters its equipment in a manner that can affect the use of this device, it must give you
Quick Set-Up2-14Verilink DPRI 2922
Verilink DPRI 2922 3-1Chapter3Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceISDN AccessFor ISDN functionality, the DPRI 2922 Craft interfa
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-2 Verilink DPRI 2922NOTE: Setting the password on the NCM has no effect on the passwords o
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-3Figure 3-1 NCM Main Menu The node master is the module responsible for
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-4 Verilink DPRI 2922Shelf and Slot ParametersTo access a DPRI module from the Main Menu, e
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-5Administration MenuWhen the shelf/slot address for the DPRI 2922 is se
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-6 Verilink DPRI 2922Table 3-3 Card Administration Submenu Commands Configuration MenuTypin
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-7T1 Port Configuration MenuTo access the T1 Port Configuration Menu, en
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-8 Verilink DPRI 2922LnLine Coding: Use this option to choose Alternate Mark Inversion (AMI
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-9When finished configuring the T1 network ports, enter X until you retu
ivVerilink DPRI 2922 User ManualDeutschVORSICHT!Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs und gleicher Qualität
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-10 Verilink DPRI 2922Figure 3-5 Configuration Submenu (FDL Options)Table 3-6 Configuratio
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-11ConfigurationMenu (TimingOptions)To access the Configuration Menu (Ti
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-12 Verilink DPRI 2922Table 3-7 Configuration Menu (Timing Options)Command Description Opt
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-13If you enable “Receive Clock from Shelf” (which is what you should do
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-14 Verilink DPRI 2922Recommended settings for timing when the DPRI 2922 is being used for
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-15Data Port Configuration MenuTo access the Data Port Configuration Men
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-16 Verilink DPRI 2922One of the functions of the Data Port Configuration Menu is to set th
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-17During normal operation, these leads should be set to LOW. By connect
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-18 Verilink DPRI 2922•Configure call profiles to define the routing characteristics for in
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-19Table 3-11PRI Port Configuration Menu CommandsCommand Description Opt
Verilink DPRI 2922 User Manualv • This product should be operated only from the type of power source indicated on the marking label and manual. If you
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-20 Verilink DPRI 2922PRI Call ProfileConfigurationMenuAn ISDN Call Profile defines the net
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-21Table 3-13Port n PRI Call Profile Configuration Menu CommandsPRI Port
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-22 Verilink DPRI 2922NOTE: After defining a call profile, remember to select option S, Sen
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-23PRI Performance /Statistics MenuTo access the PRI Performance/Statist
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-24 Verilink DPRI 2922Figure 3-15 PRI Performance/Statistics Menu Table 3-15PRI Performance
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-25Figure 3-16 Port 1 PRI 15 Minute Performance DataWhen the options pre
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-26 Verilink DPRI 2922Diagnostics MenuThe Diagnostics Menu is used to troubleshoot the netw
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-27Table 3-17T1 Port Diagnostics Menu CommandsCommand Description Option
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-28 Verilink DPRI 2922When finished configuring the T1 port diagnostics parameters, enter X
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-29Figure 3-20 Data Port Diagnostics MenuData Port Diagnostics Menu Comm
viVerilink DPRI 2922 User Manual
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-30 Verilink DPRI 2922Figure 3-21 Performance/Status MenuUse the Performance/Status Menu to
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-31Performance / Status Menu (24hr T1 Performance Data Summary)Select P
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-32 Verilink DPRI 2922Table 3-19Performance/Status Menu (24hr T1 Performance Data Summary)
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-33When one of these options is selected, the previous 24 hour data is d
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-34 Verilink DPRI 2922Figure 3-24 Counter MenuTable 3-20Counter Menu CommandsNet Port Alarm
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-35Net Port Alarm Threshold Configuration MenuThe Performance/Status Men
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-36 Verilink DPRI 2922Table 3-22Net Port Alarm Threshold Configuration Menu CommandsCommand
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-37Net Port Alarm Theshold Status MenuTo display the Net Port Alarm Thre
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-38 Verilink DPRI 2922Figure 3-27 Net Port Alarm Threshold StatusCircuit Manager MenuTo acc
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-39The port line code selection (for example, 56k or 64k circuits) can l
Verilink DPRI 2922 viiTable 1Use this detachable checklist to guide your installation of the DPRI 2922 for ISDN capabilitiesWhen Information Required
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-40 Verilink DPRI 2922Add Circuit SubmenuUse this option to create a new circuit. Specify t
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-41Figure 3-29 Add Circuit SubmenuTable 3-24Add Circuit Submenu Commands
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-42 Verilink DPRI 2922Search Circuit SubmenuUse this option to search for or list existing
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-43Delete Circuit SubmenuUse this option to remove existing circuits.Fig
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-44 Verilink DPRI 2922Figure 3-32 Edit Circuit SubmenuA [127.255.255.0] [1,2] DPRI 2922 >
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-45Table 3-27Edit Circuit Submenu CommandsCommand Description OptionsN N
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-46 Verilink DPRI 2922Manufacturing InfoTo display the firmware versions and CIM types, cho
Configuring the DPRI 2922 Via the NCM 2000 Craft InterfaceVerilink DPRI 2922 3-47NOTE: The Manufacturing Information window displays information about
Configuring the DPRI 2922 Via the NCM 2000 Craft Interface3-48 Verilink DPRI 2922
Verilink DPRI 2922 4-1Chapter4TroubleshootingController card(s) poll the various modules for alarms. If alarm reporting is enabled for the node and fo
viii Verilink DPRI 2922
Troubleshooting4-2 Verilink DPRI 2922Status CodeThe status code column displays a decimal code when using an ASCII terminal. (Varies depending on SNMP
TroubleshootingVerilink DPRI 2922 4-3What To Do About AlarmsSome alarms clear after the user-configured timeout has expired. Other alarms require corr
Troubleshooting4-4 Verilink DPRI 2922Alarm ListFault conditions can result in critical, major, or minor alarms. In addition, a fault condition can als
TroubleshootingVerilink DPRI 2922 4-5Loss of Frame Alignment (E1 Only)This condition occurs when three consecutive in-error frame alignment signals (w
Troubleshooting4-6 Verilink DPRI 2922Interpreting Front Panel LEDsThe LED indicators on the front panel of the DPRI 2922 module display errors caused
TroubleshootingVerilink DPRI 2922 4-7Data Port LEDs Data Port LEDs 1 and 2 display the status for their respective ports.Table 4-3 Data Port LED Indic
Troubleshooting4-8 Verilink DPRI 2922
DPRI 2922IndexVerilink DPRI 2922 Index-1Numerics1/8test pattern 3-272N1 5-1test pattern 3-272N20-1test pattern 3-273 in 24 3-2755 Octettest pattern 3-
Index-2 Verilink DPRI 2922Data Set Ready 3-16Data Terminal Equipment 3-15DCE 3-15default valuespassword 3-1Degraded Minutes 3-32delete circuits 3-40di
Verilink DPRI 2922 Index-3registers 3-33test counters 3-28, 3-29RLB 3-27Ssecondaryauto restore 3-12card slot number 3-13synchronization 3-12SEF 3-32Se
Table of ContentsDPRI 2922Verilink DPRI 2922 viiDPRI 2922 Dual-Port ISDN Primary Rate Interface ...
Index-4 Verilink DPRI 2922
VERILINK CORPORATION127 JETPLEX CIRCLE, MADISON, ALABAMA 35758TEL: (800) 837-4546September 1999P/N 880-503142-001-A1