Verilink QUAD/IMUX User ManualSeptember 1999P/N 880-502392-001-B1
Overview1-2 Verilink QUAD/IMUX User ManualFeaturesEach Inverse Multiplexer system requires at least two different modules: the IMUX 2160 and the QUAD
OverviewVerilink QUAD/IMUX User Manual 1-3Module DetailsThis section provides detail on the features of the two Inverse Multiplexer modules, the QUAD
Overview1-4 Verilink QUAD/IMUX User ManualThe QUAD 2164 module exchanges user data with the IMUX 2160 across Data Bus A on the shelf backplane.IMUX 21
OverviewVerilink QUAD/IMUX User Manual 1-5Figure 1-2 Multiline shelf “A” Bus SegmentationModule PlacementEach Inverse Multiplexer application must hav
Overview1-6 Verilink QUAD/IMUX User ManualInverse Multiplexer ConfigurationsEach QUAD 2164 module can aggregate up to four T1 or E1s. Two QUAD 2164 mo
OverviewVerilink QUAD/IMUX User Manual 1-7SpecificationsTable 1-1 lists the specifications of the QUAD 2164 module.Table 1-1 QUAD 2164 ModuleTable 1-2
Overview1-8 Verilink QUAD/IMUX User ManualFigure 1-6 QUAD 2164 Front Panel with CIM Rear PanelsTable 1-3 IMUX 2160 module2164QUADLOCALSYSMANAGEMENTSNM
OverviewVerilink QUAD/IMUX User Manual 1-9Table 1-4 DTE Interface Modules for IMUX 2160DTE Adapter CablesFor the HSSI interface type, the connector pr
Overview1-10 Verilink QUAD/IMUX User ManualFigure 1-7 IMUX 2160 Front Panel with CIM Rear Panels2160IMUXDATASTATNETSTATCNTRLHSSIDIM2660STATCNTRL V.35
Verilink QUAD/IMUX User Manual 2-1Chapter2Quick Set-UpQuick Set-Up takes you through the steps necessary to configure a typical Inverse Multiplexer co
iiVerilink QUAD/IMUX User ManualCopyright NoticeCopyright 1999 Verilink Corporation. All rights reserved.This document does not create any express o
Quick Set-Up2-2 Verilink QUAD/IMUX User ManualNOTE:When more than one QUAD/IMUX is installed in the same shelf all QUAD/IMUX installations in that she
Quick Set-UpVerilink QUAD/IMUX User Manual 2-3Connect a TerminalThe terminal used to configure the QUAD/IMUX may be any ASCII terminal or terminal emu
Quick Set-Up2-4 Verilink QUAD/IMUX User ManualConfigure Central SiteUse this step-by-step procedure at the central site or whenever an NCM 2000 is use
Quick Set-UpVerilink QUAD/IMUX User Manual 2-5Figure 2-3 NCM 2000 Node Administration MenuSet Shelf Type5. Select the Shelf Type submenu by typing “H”
Quick Set-Up2-6 Verilink QUAD/IMUX User ManualFigure 2-4 NCM 2000 Node Administration Menu6. Set the shelf type to 2200 QUAD/IMUX Shelf 2200 QUAD/IMUX
Quick Set-UpVerilink QUAD/IMUX User Manual 2-7configuration requires that the QUAD 2164 modules use Bus C because the NCM is using Bus C (NCM shelf ty
Quick Set-Up2-8 Verilink QUAD/IMUX User ManualNOTE:Whenever a Verilink Craft interface presents a prompt with an uppercase character and a lowercase “
Quick Set-UpVerilink QUAD/IMUX User Manual 2-916. This example configuration has three QUAD 2164 modules which each connect to the same carrier, and t
Quick Set-Up2-10 Verilink QUAD/IMUX User ManualFigure 2-8 QUAD 2164 Alarm Menu20. Type “L” to select the Line Restoral Menu.Figure 2-9 QUAD 2164 Line
Quick Set-UpVerilink QUAD/IMUX User Manual 2-1123. Use the “I1”, “I2”, “I3”, and “I4” commands to set the Clear Interval to 30 seconds. Now, if a T1 f
Verilink QUAD/IMUX User Manualiii • If the telephone company alters its equipment in a manner that can affect the use of this device, it must give you
Quick Set-Up2-12 Verilink QUAD/IMUX User Manual3. Use the “H” command to select MANUAL for DTE handshaking. Use the “DSR”, “CTS” and “DCD” commands to
Quick Set-UpVerilink QUAD/IMUX User Manual 2-13Central Site SummaryThis concludes the necessary steps to begin passing data at the central site. Other
Quick Set-Up2-14 Verilink QUAD/IMUX User ManualFigure 2-11 QUAD 2164 Main MenuWARNING Never configure any SLIP IP address through theCraft interface
Quick Set-UpVerilink QUAD/IMUX User Manual 2-15Figure 2-12 QUAD 2164 Configuration MenuConfigure Port 14. Type “I1” and reply “y” to enable port 1.5.
Quick Set-Up2-16 Verilink QUAD/IMUX User ManualFigure 2-13 QUAD 2164 Timing Menu9. This site has one QUAD 2164 module which connects to four T1 circui
Quick Set-UpVerilink QUAD/IMUX User Manual 2-17Configure Line Restoral10. Type “A” and select “2” to enable card alarm reporting.11. Use “P1”, “P2”, “
Quick Set-Up2-18 Verilink QUAD/IMUX User ManualNOTE:When Rx ClockRx ClockRx ClockRx Clock is set to “INVERT” the clock signal is actually normal. When
Quick Set-UpVerilink QUAD/IMUX User Manual 2-1922. Press ENTER to refresh the display of the IMUX 2160 Configuration Menu. A column of XXXX characters
Quick Set-Up2-20 Verilink QUAD/IMUX User Manual
Verilink QUAD/IMUX User Manual 3-1Chapter3E1 Configuration MenusThe menus included in this chapter apply to a standalone configuration. The same menus
ivVerilink QUAD/IMUX User ManualDeutschVORSICHT!Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs und gleicher Qualität
E1 Configuration Menus3-2 Verilink QUAD/IMUX User ManualFigure 3-1 Quad 2164 Main MenuTable 3-1 Main Menu CommandsShelf/Slot SelectionTo select a shel
E1 Configuration MenusVerilink QUAD/IMUX User Manual 3-3E1 QUAD Configuration MenuTo configure the QUAD 2164 E1 options, select the QUAD shelf and slo
E1 Configuration Menus3-4 Verilink QUAD/IMUX User ManualE1 Alarm OptionsTo configure the QUAD 2164 Alarm Options, type “A” from the QUAD 2164 Configur
E1 Configuration MenusVerilink QUAD/IMUX User Manual 3-5E1 Line Removeand Restore MenuTo configure the Line Restoral Options, type “L” from the QUAD 2
E1 Configuration Menus3-6 Verilink QUAD/IMUX User ManualFigure 3-4 E1 Line Remove/Restore Configuration MenuTable 3-4 E1 Line Remove/Restore Configura
E1 Configuration MenusVerilink QUAD/IMUX User Manual 3-7Figure 3-5 E1 Timing Options MenuTable 3-5 E1 Timing Options MenuField Name DescriptionPC (P
E1 Configuration Menus3-8 Verilink QUAD/IMUX User ManualE1 Node AdministrationThe QUAD 2164 Main Menu is the access point for both of the Inverse Mult
E1 Configuration MenusVerilink QUAD/IMUX User Manual 3-9Figure 3-6 QUAD 2164 Administration Menu-- ACE CONTROLLER ADMINISTRATION MENU ---- ACE CONTR
E1 Configuration Menus3-10 Verilink QUAD/IMUX User ManualFigure 3-7 QUAD 2164 Administration Menu, Network Parameters Table 3-6 E1 QUAD 2164 Administr
E1 Configuration MenusVerilink QUAD/IMUX User Manual 3-11Slip Address Do not configure SLIP on the QUAD 2164. There is no physical interface on the QU
Verilink QUAD/IMUX User Manualv • This product should be operated only from the type of power source indicated on the marking label and manual. If you
E1 Configuration Menus3-12 Verilink QUAD/IMUX User ManualIMUX ConfigurationThis section provides information about the E1 IMUX 2160 module configurati
E1 Configuration MenusVerilink QUAD/IMUX User Manual 3-13F Ref Clk Phase—Selects or displays the status of the reference clock phase. Valid choices ar
E1 Configuration Menus3-14 Verilink QUAD/IMUX User Manual5 TM—TM stands for Test Mode, it is a lead defined in many synchronous serial interface proto
Verilink QUAD/IMUX User Manual 4-1Chapter4T1 Configuration MenusThe menus included in this chapter apply to a standalone configuration. Similar menus
T1 Configuration Menus4-2 Verilink QUAD/IMUX User ManualFigure 4-1 QUAD 2164 Main MenuTable 4-1 Main Menu CommandsShelf/Slot SelectionTo select a shel
T1 Configuration MenusVerilink QUAD/IMUX User Manual 4-3T1 QUAD Configuration MenuTo configure the QUAD 2164 T1 options, select the QUAD shelf and slo
T1 Configuration Menus4-4 Verilink QUAD/IMUX User ManualFDL OptionsTo configure the Facility Data Link (FDL) options from the QUAD 2164 Configuration
T1 Configuration MenusVerilink QUAD/IMUX User Manual 4-5Table 4-3 T1 FDL Options MenuT1 Alarm OptionsTo configure the QUAD 2164 alarm options, type “A
T1 Configuration Menus4-6 Verilink QUAD/IMUX User ManualFigure 4-4 T1 Alarm Options MenuTable 4-4 T1 Alarm Options Menu-- QUAD 2164 CONFIGURATION MEN
T1 Configuration MenusVerilink QUAD/IMUX User Manual 4-7Line Restoral OptionsThe IMUX 2160 will immediately stop using any of the assigned T1 ports wh
viVerilink QUAD/IMUX User Manual
T1 Configuration Menus4-8 Verilink QUAD/IMUX User ManualT1 Timing OptionsTo configure the QUAD 2164 timing options, type “T” at the Configuration Menu
T1 Configuration MenusVerilink QUAD/IMUX User Manual 4-9Restore DefaultsRestores the factory default settings. See Appendix A, "Default Configura
T1 Configuration Menus4-10 Verilink QUAD/IMUX User ManualT1 Node AdministrationThe QUAD 2164 Administration Menu is used to set the TCP/IP and Verilin
T1 Configuration MenusVerilink QUAD/IMUX User Manual 4-11CAUTION Never configure any SLIP IP address or SLIP Subnet mask in any QUAD 2164 module. The
T1 Configuration Menus4-12 Verilink QUAD/IMUX User ManualTable 4-6 T1QUAD 2164 Administration Menu Command/Field DescriptionD) Set DateT) Set TimeZ)
T1 Configuration MenusVerilink QUAD/IMUX User Manual 4-13M Modem Parameters—Not supported by this product.R Reset Card—Restarts the QUAD 2164 without
T1 Configuration Menus4-14 Verilink QUAD/IMUX User ManualIMUX ConfigurationThis section discusses the T1 IMUX 2160 module configuration.T1 IMUX Config
T1 Configuration MenusVerilink QUAD/IMUX User Manual 4-15R Rx Clk Phase—Selects or displays the status of the receive clock phase. Valid choices are N
T1 Configuration Menus4-16 Verilink QUAD/IMUX User Manual5 TM—TM stands for Test Mode, it is a lead defined in many synchronous serial interface proto
Verilink QUAD/IMUX User Manual 5-1Chapter5Performance MonitoringThis chapter provides information about the QUAD/IMUX performance and status menus, in
Table of ContentsVerilink QUAD/IMUX User Manual viiOverview...
Performance Monitoring5-2 Verilink QUAD/IMUX User ManualIMUX 2160 LEDsThe IMUX 2160 front panel has three tri-state LEDs labeled.•DATA•STAT•NETRed NET
Performance MonitoringVerilink QUAD/IMUX User Manual 5-3QUAD 2164 Performance MonitoringTo view performance and status information for the QUAD 2164,
Performance Monitoring5-4 Verilink QUAD/IMUX User ManualAIS Rx/Tx Displays the number of Alarm Indication Signal (AIS) Seconds (received and transmitt
Performance MonitoringVerilink QUAD/IMUX User Manual 5-5Figure 5-2 QUAD 2164 Performance/Status Menu, E1 versionTable 5-2 QUAD 2164 Performance/Status
Performance Monitoring5-6 Verilink QUAD/IMUX User ManualA sample Errored Seconds report is shown in Figure 5-3. To see this display for Port 2, type “
Performance MonitoringVerilink QUAD/IMUX User Manual 5-7Figure 5-3 Sample 24 Hour ES-P Performance Data ScreenA sample of Threshold Status is shown in
Performance Monitoring5-8 Verilink QUAD/IMUX User ManualTable 5-3 Threshold Status DisplayT1 Alarm MonitorTo enable or disable the alarm monitor, type
Performance MonitoringVerilink QUAD/IMUX User Manual 5-9IMUX Performance MonitoringTo view performance and status information for the IMUX 2160, selec
Performance Monitoring5-10 Verilink QUAD/IMUX User ManualTable 5-4 IMUX Performance/Status MenuField Name DescriptionData Port Type Displays the type
Verilink QUAD/IMUX User Manual 6-1Chapter6DiagnosticsThis chapter contains information about the QUAD/IMUX Diagnostics. The Diagnostics Menu is design
viii Verilink QUAD/IMUX User ManualCraft Interface...
Diagnostics6-2 Verilink QUAD/IMUX User ManualTable 6-1 QUAD 2164 Diagnostic MenuFigure 6-2 Loopbacks IllustratedCommand DescriptionLoop Type This fiel
DiagnosticsVerilink QUAD/IMUX User Manual 6-3IMUX DiagnosticsThe Diagnostics Menu for the IMUX 2160 is shown in Figure 6-3. Figure 6-3 IMUX Diagnostic
Diagnostics6-4 Verilink QUAD/IMUX User ManualFrame StatusShows that the selected IMUX 2160 module has recognized and synchronized with the IMUX frame
Verilink QUAD/IMUX User Manual A-1AppendixADefault ConfigurationThis appendix
A-2 Verilink QUAD/IMUX User ManualTo access the threshold defaults for the QUAD 2164, select the QUAD Configuration Menu. Select menu option “T” to a
Verilink QUAD/IMUX User Manual A-3Figure A-3 Configuration Menu - QUAD Net Port Alarm, Group B Threshold DefaultsFigure 4 shows the IMUX Configur
A-4 Verilink QUAD/IMUX User ManualFigure A-5 QUAD Configuration Menu, Timing Options Defaults -- QUAD 2164 CONFIGURATION MENU (TIMING OPTIONS)----
IndexVerilink QUAD/IMUX User Manual Index-1Numerics458-102119-008 2-3458-501594-001 1-9458-502045-001 1-9458-502059-001 1-9AACPaddress 3-4, 4-6communi
Index-2 Verilink QUAD/IMUX User ManualDSR, see also Data Signal Ready 3-13, 4-15DTEHandshake parameter 3-13, 4-15Type parameter 3-13, 4-15DTR, see al
Verilink QUAD/IMUX User Manual Index-3Performance Report Message 4-4Command/Response 4-5PLB BOP, Payload Loopback 4-5Poll Mode option 4-5PRM C/R, see
Verilink QUAD/IMUX User Manual 1-1Chapter1OverviewThis manual describes Verilink’s Access System 2000 T1/E1 Inverse Multiplexer system (QUAD/IMUX). It
Index-4 Verilink QUAD/IMUX User Manual
VERILINK CORPORATION145 BAYTECH DRIVESAN JOSE, CALIFORNIA 95134TEL: (408) 945-1199FAX: (408) 262-6260July 1999P/N 880-502392-001-B
Komentarze do niniejszej Instrukcji