T1 ESF CSUReference ManualMay 200234-00309.B

Strona 2

x ABOUT THE T1 ESF CSUCustomer Service and Technical SupportVerilink provides easy access to customer support information through a variety of service

Strona 3

Returning a Unit to Verilink xicontacting us at the e-mail addresses provided below. Verilink will respond to e-mailed requests for support durin

Strona 4

xii ABOUT THE T1 ESF CSU❥Mode of shipment required (second-day air is the normal mode of shipment for all returned material unless otherwise specified

Strona 5

Introduction 11GENERAL INFORMATIONIntroductionVerilink’s T1 ESF CSU provides an economical solution for providing the T1 interface between custom

Strona 6

2 GENERAL INFORMATIONSpecificationsNetwork InterfaceLine Rate:1.544 Mbps (± 50 ppm) Line Framing:D4 or ESF Line Code:AMI or B8ZSLine Impedance:balance

Strona 7 - Table of Contents

Introduction 32INSTALLATION AND CONFIGURATIONIntroductionThis chapter contains information and instructions required to prepare Verilink’s T1 ESF

Strona 8

4 INSTALLATION AND CONFIGURATION✦external DC power supply ✦reference manual✦adhesive strips✦two 9-foot RJ48-to-RJ48 cables (part number 9-1544-619-009

Strona 9

Configuration 5Power ConnectionPlug the connector from the power supply into the unit. Plug the transformer into an appropriate grounded outlet.

Strona 10 - Support from Verilink

6 INSTALLATION AND CONFIGURATIONNOTICE: Position SW1-1 is not enabled for use. EQ LBOPositions SW1-2, SW1-3, and SW1-4 set the EQ LBO (line build out)

Strona 11 - Returning a Unit to Verilink

Introduction 73TESTINGIntroductionThis chapter describes the diagnostic and test features of Verilink’s T1 ESF CSU. The unit is controlled manua

Strona 12 - T1 ESF CSU

ii Copyright NoticeCopyright © 2002 Verilink Corporation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribe

Strona 13 - NFORMATION

8 TESTINGNetworkPosition SW1-6 sets network loopback functions. NET LOOP can be set to Auto or Manual. “Auto” enables the unit to respond to network l

Strona 14 - Specifications

Test Jacks 9T1.403 / 54016 PLB Unloop: The unit supports T1.403 FDL payload loopback unloop command messages (00110010 11111111 repeating). Test

Strona 16 - Connections

AFFIDAVIT FOR THE CONNECTION OF CUSTOMER PREMISES EQUIPMENT TO 1.544 MBPS AND/OR SUBRATE DIGITAL SERVICES For work to be performed in the certified te

Strona 17 - Configuration

I attest that the operator(s) maintainer(s) of the digital CPE responsible for the establishment, maintenance, and adjustment of the encoded analog co

Strona 18

iiiNotice to Usersof 1.544 MbpsServiceThe following instructions are provided to ensure compliance with FCC Rules, Part 68.1All direct connections to

Strona 19

iv network protective, operational and safety requirements. The Industry Canada does not guarantee the equipment will operate to the user’s satisfact

Strona 20

v•Unplug the equipment from the wall outlet and refer servicing to qualified service personnel under the following conditions:•When the power supply c

Strona 22

viiTable of Contents About the T1 ESF CSUAbout this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 24

About this Manual ixABOUT THE T1 ESF CSUAbout this ManualThis is a reference manual. It provides information about unit installation, configurati