Configuration Options for AS2000 and ConnecT1 Plus
Access Manager 2000 User Manual
5
-
77
If you set the Retrieve Far-End Data option to YES, you must
also set the Retrieve Near-End Data option to YES, and there
must be a circuit built between the near-end and far-end circuit elements.
Do not set Retrieve Far-End Data to YES at both the near-end
and far-end circuit elements. For example, set Retrieve Far-End
Data to YES for the near-end NCC, CCC, or TAC and set Retrieve
Far-End Data to NO for far-end circuit element. The defaults for
these options is NO, except near-end Net Use , which is YES.
This option must be set to YES and the Installed and
Operational option must also be set to YES to enable Access
Manager to configure the selected CSU circuit elements.
The options following Save Configuration to CSU are
downloaded to the CSU circuit element when is pressed. If this
option is set to NO, any changes made are saved in the database but are
not downloaded to the CSU circuit element.
CSUs can report alarm conditions to Access Manager when excessive
errors occur or the line service is degraded.
If you don’t want the CSU to report alarm conditions to Access Manager,
your choice is simple. Set the Enable Alarm Reporting field to
NO.
To allow the CSU to report alarm conditions to Access Manager:
1. Set Enable Alarm Reporting to YES.
2. Make sure that in the Node Configuration screen of the parent node,
you have:
• set the Enable Alarm Reporting to YES
• downloaded the alarm path for that node
Otherwise, the CSU will send alarms to the node controller, but the
node controller will not forward these alarms to Access Manager.
Save
Configuration to
CSU
F5
Enable Alarm
Reporting