Configuring and Installing the Centum Series
3-8
Access System Centum Series User Manual
Ye s MUST be chosen if the network supplier is a common carrier,
such as a telephone company. If the network is private, the selection
is a user option.
10. ESF Reporting Format. This entry describes the types of ESF
network commands that the Centum Series will respond to. It has no
meaning for D4 networks: see Framing (item #4, above). With ESF
networks, this information must be obtained from the network
supplier.
Repeatedly
SELECT to choose between AT&T Technical Reference
54016 and ANSI specification T1.403.
11. Clear Registers. Repeatedly
SELECT to choose between Ye s and
No. Ye s is the recommended choice.
When commanded by the network supplier, Centum Series will
transmit stored error information to the supplier.
A Ye s entry will cause Centum Series to clear all error counts when
the unit is powered down and back up again.
A No entry will allow potentially invalid registers in preparation for
transmission to the network supplier.
NI Configuration