4 AS420 Reference Manual
Specifications
Generic Interface Requirements (120 Ω
Ω Ω
Ω and 75 Ω
ΩΩ
Ω)
E1 Interface
Line Rate: 2.048 Mbps (± 32 ppm)
Framing: ITU-T G.704 (with or without CRC-4) G.703
Line Code: HDB3
Input Level: E1 to 6 decibels
Pulse Width: 244 (± 41) nanoseconds at half amplitude
Pulse Afterkick: 10 to 30 percent of pulse peak
T1 Interface
Line Rate: 1.544 Mbps (± 32 ppm)
Framing: D4 or ESF
Line Code: AMI or B8ZS
Input Level: 0 to -36 decibels
Pulse Width: 344 (± 45) nanoseconds at half amplitude
Pulse Afterkick: 10 to 30 percent of pulse peak
120 Ω
Ω Ω
Ω Termination
Interface: RJ-48C
Impedance: 120 Ω, balanced
Output Level: 3.0 (± 0.3) volts (base-to-peak)
75 Ω
Ω Ω
Ω Termination
Interface: BNC - coax
Impedance: 75 Ω, unbalanced
Output Level: 2.37 (± 0.24) volts (base-to-peak)
E1 Equipment Interface
N×64 kbps rate... for unframed E1: N=32;
for framed E1 without CAS: N=1 to 31;
for framed E1 with CAS: N=1 to 15 and 17 to 31
120 Ω
Ω Ω
Ω Termination
Interface: RJ-48C
Impedance: 120 Ω, balanced
Komentarze do niniejszej Instrukcji