Configuration 3-1PRISM 4151
3. Configuration
The PRISM 4151 can be configured through manual switch
settings and/or through a VT100 terminal connection to the
supervisory port.
All default options in this manual are underlined
.
Hardware Configuration
Hardware configuration is set using two dual in-line pack-
age (DIP) switches located on the rear of the unit. These
switches allow you to configure simple applications. Refer
to Figure 3-6 for switch locations. A removable configura-
tion guide (45-00105) is included in the back of this manual.
Switch S1
Switch S1 (Figure 3-7) configures the antistream timer,
V.54 loop, circuit assurance, and loop mode.
Antistream Timer:
Switch S1-1 allows the DDS transmit-
ter to send DMI (Data Mode Idle / all ones) if the RTS
remains enabled long enough for a timeout to occur.
Choices are Off (Dn)
or 30 seconds (Up).
V.54 Loop:
Switch S1-2 enables (Dn)
or disables (Up) the
unit’s ability to respond to incoming V.54 loop/unloop code.
If set to enable, the PRISM 4151 will loop or unloop. If set
to disable, loop codes are ignored.
Circuit Assurance:
Switch S1-3 configures the CTS/RTS
sequence. When Circuit Assurance is disabled (Dn)
, CTS
follows RTS. When enabled (Up), CTS follows RTS if DCD
is also enabled (or set to On).
Loop Mode:
Switch S1-4 determines the loop direction for
the transmit and receive data as either bidirectional (Dn)
or
unidirection (Up). Refer to page 4-1 for more information
concerning the loop modes and with respect to testing.
Switch S2
Switch S2 (Figure 3-8) configures the boot mode, DDS
mode, timing source, CTS delay, RTS, CTS, DCD hand-
shake, remote/local loopback, and DTR alarm.
Boot Mode
: Switch S2-1 determines whether the unit con-
figures itself from the DIP switches or from the saved soft-
ware configuration. If set to boot from saved software
configuration (Up), the switch settings are ignored. If set to
boot from switches (Dn)
, the unit reads the DIP switches on
power-up and configures accordingly. Once running, config-
uration changes can be made through the terminal interface,
overriding the switch settings.
DDS Mode:
Switch S2-2 establishes the DDS mode as
either DDS II/64 kbps (Dn)
or DDS I/56 kbps (Up).
Timing Source
: Switch S2-3 and S2-4 determine the unit
clocking source. The most common timing source for CSU/
DSU applications is the network. The PRISM 4151 may
also be optioned to time from an internal standard or from
the high speed data interface as shown in Table 3-H.
SUPVSLIPLAN
NET
V.35
115 VAC
60 HZ
S2 S1
Figure 3-6 PRISM 4151 Rear Panel
7654321 8
V.54 Loop
Circuit Assurance
Dn
Up
Loop Mode
Switch
S1
Antistream Timer
Not Used
Not Used
Not Used
Not Used
Figure 3-7 Switch S1
7654321 8
DDS Mode
Timing
Remote/Local
DTR Alarm
Loopback
CTS Delay
Source
Dn Up
RTS, CTS, DCD
Handshake
Figure 3-8 Switch S2
Boot Mode