SCM Overview
1-6 Verilink SCM
Alarm Relay
The NIM rear panel provides alarm relay outputs. The Form C alarm
relay provides normally open (NO), normally closed (NC), and
common (CO) contacts. The relay is triggered by alarms that may
occur within the node, including the failure of one SCM in a node
with redundant SCMs.
Figure 1-3 NIM 3000 Rear Connector Module, Rear Panel
Craft Interface
The SCM Craft interface is a menu-driven ASCII user interface. It is
supported by all modules in the node. It can be accessed locally, or
remotely via Telnet over SLIP or Ethernet.
An SCM installed in each node unifies a network via inband
management. A local SCM can support a terminal session extended
to the remote SCM. The remote SCM in turn, can communicate with
the firmware of the application modules in its node.
Each local SCM can manage one node of one shelf containing up to
13 modules.
Figure 1-4 shows an example QUAD T1 application.
Management PRI RS-232 RJ-45 ACP management over RS-232
Management EXT RS-232 RJ-45 ACP management over RS-232
Ethernet 10 Mbit/s Ethernet AAUI TCP/IP/Telnet/SNMP/FTP via external
Ethernet transceiver (supplied)
Port Label on NIM 3000 Interface Connector Protocol Support
ALARM
RELAY
NO COM NC
311-10XXXX001
INPUT
EXT TIMING
SLIP
ETHERNET
PRI EXT
NIM
3000
DB-25 male
Dual RJ-45
AAUI-14 female