The four columns of the status table are as follows:
The table provides error status and alarm threshold information for the
following error parameters:
LOS
Sets the Loss of Signal threshold. A LOS is a 1-second period in which the
DDS received signal is interrupted. The default value is None.
OOF
Sets the Out of Frame threshold. An OOF is a 1-second period in which a
frame sync loss occurred. The default value is None.
OOS
Sets the Out of Service threshold. An OOS is a 1-second period during which
the Out of Service code is received. The default is None.
BPV
Sets the Bipolar Violation Errored threshold. A BPV is a 1-second period in
which at least one bipolar violation occurred. The default is None.
Reset Timer
The status table also provides a means for establishing the Reset Timer
threshold. This read/write field is used to establish the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset. The default value is 30.
The Network screen provides the following user-activated buttons:
Serial 1 and Serial 2 Screens
Because the Serial 1 and Serial 2 screens have the same menus, only the
Serial 1 screen is displayed below in Figure 3.5. The Serial screens let you
view and make configuration changes to the unit’s Serial 1 or Serial 2
interface as described below. To make changes to any Serial port parameter,
simply set the parameter to the desired selection and press the “Submit”
button.
Status Displays the current status of the network port.
Alarm Displays the alarm value of the network port. The unit
declares an alarm as soon as the count exceeds the established
threshold.
Count Displays the number of events or occurrences of this
condition that have been detected.
Threshold This forced-choice field can be set to a desired threshold for a
specific error condition. Available threshold choices are
None, 1, 2, 3, 4, 5, 10, 20, and 30.
Button Function
Submit Sets any values that have been changed.
Clear Alarms Resets the alarm conditions and counts to zero.