Verilink WANsuite 5370 (34-00310.D) Product Manual Instrukcja Użytkownika Strona 53

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 235
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 52
Web Server Interface 3-23
FrameStart Auto
Discovery
When this parameter is set to “Yes,” the unit will send FrameStart discovery
and delay frames to each DLCI it learns as soon as the DLCIs are set active.
This is required to calculate round trip delay as well as to discover remote
WANsuite/FrameStart units. This parameter should be set to “Yes” only on
network services that have a WANsuite/FrameStart unit at the far end of the
frame relay connection. Also if set to “Yes,” the unit will gather SLA
parameters such as frame and data delivery ratio as defined in the Frame
Relay Forum Implementation, FRF.13. Those gathered statistics are then
displayed on the DLCI Statistics screen as shown on page 3-37.
Values:No, Yes
Default:No
Round Trip Delay Size
(bytes)
Specifies the frame size (in bytes) of packets making the round trip.
Round Trip Delay Rate
(secs)
Specifies the rate (in seconds) at which Round Trip Delay packets are sent.
Status and Alarms Table
The table displayed at the bottom of the Frame Relay Service Details screen
reports on the status and condition of LMI parameters and on Receive/
Transmit alarms and thresholds. Alarm threshold levels may be changed by
entering a new threshold value in the appropriate field of the table and
clicking the “Submit” button. Table fields are described below.
Active
Read-only field shows whether or not (Yes or No) an alarm is active.
LMI Type
Read-only status indicates ANSI, CCITT, LMI rev. 1, or Unknown.
FrameStart Status
Read-only status indicates Sourcing, Monitoring, or 0.
Rx Invalid Threshold
Number of invalid frames received during a 15-minute interval after which an
invalid alarm will be triggered. Default of “0” disables this alarm.
Rx Invalid Alarm
Status of this alarm indicates OK or Alarmed.
Tx Threshold
Number of bits per second sent during a 15-minute interval after which a Tx
alarm will be triggered. Default of 0 disables this alarm.
Tx Alarm
Status of this alarm indicates OK or Alarmed.
Rx Threshold
Number of bits per second sent during a 15-minute interval after which an Rx
alarm will be triggered. Default of 0 disables this alarm.
Rx Alarm
Status of this alarm indicates OK or Alarmed.
Przeglądanie stron 52