Verilink AS2000: The Basics (880-502981-001) Product Manual Instrukcja Użytkownika Strona 69

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 179
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 68
Monitoring and Troubleshooting
Verilink Access System 2000: The Basics 5-3
Interpreting
Alarms
The alarm list displays the following information about alarms
(This information may vary depending on the controller module
and management method used):
Whenever the system power cycles and any module does a
self-test
Power supply input is lost
A default or user-designated threshold is exceeded
A Yellow Alarm is received from the network (DS1)
An unframed all-ones or alarm indication signal (AIS) is
received from the network
There is a Loss of Signal (LOS) or Loss of Frame (LOF)
A loopback is present
A module fails
A module is removed from the shelf
Figure 5-1 Alarm Buffer
Alarm Description
The alarm description column lists the text which is:
printed on the display
saved to the alarm buffer/database
Alarm
Classification
Verilink classifies alarms into the following severities:
Critical
Major
Minor
Warning
Info
Cleared
Problem Types
These classifications are further categorized into the following
problem types:
LOS
LOF
Error
[1,1] DCSU 2911 > o
DCSU 2911 [1,1] AIS Major Alarm port 1 3-09-98 18:38:35
DCSU 2911 [1,1] AIS Threshold Cleared port 1 3-09-98 18:37:17
Press enter to continue
Alarm Description
Alarm Classification
Alarm Date and Time
Module Type
Shelf/Slot
Location
Port
Przeglądanie stron 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 178 179

Komentarze do niniejszej Instrukcji

Brak uwag