Przeglądanie stron 28
Operation 23
MAIN MENU ALARMS NETWORK: OK
LOSS, 5
OOSS, 5
BPVS, 0
FR NET
: OK, LOCAL, SOS, DLCI
RESET TIMER: 000 – 900, 30
§
RESET ALARMS?
PERFORMANCE NET PERFORMANCE RCV LVL: 0.0 dB, 7.3 dB, 13.6 dB, 19.7 dB, 26.0 dB,
32.3 dB, 38.4 dB, 44.4 dB, 50.5 dB
LOSS
OOSS
BPVS
CLEAR HISTORY?
FR PERFORMANCE LMI TYPE: ORIG, ANSI D, ITU A
PCKT SRC: UNI, NI
DLCI TOTAL: 000999
DLCI Screen
CLEAR DLCI? TEST DLCI xxx?
MAINTENANCE LOOP: NONE?, ENABLE LLB?, ENABLE DLB?, ENABLE LCL
ENABLE V54?, ENABLE RMT V54?, ENABLE RMT DLB
BERT: NONE,
EN. NET BERT? TP: MARKS, SPACES, 511, 2047
EN. DTE BERT? INJECT ERROR?
ERR CNT = 0000065356
CLEAR ERR CNT?
DTE CONFIG RATE: 56 Kbps, 64 Kbps
1
DTE CLOCK: NOR, INV
TXCC CLOCK: EN, DIS
DTE DATA: NOR, INV
CTS: NORMAL, FORCED ON
CTS DELAY: 000–255
DCD: NORMAL, FORCED ON
DSR: NORMAL, FORCED ON
DTR: NORMAL, IGNORED
FRAME RLY CONFIG LMI MODE: OFF, ON, MON
UNIT ID: 000 999
N391: 001255, 006
N392: 01–10, 03
N393: 01–10, 04
T391: 05–30, 10
PVC MODE: DIS, EN
SOS TX: EN, DIS
SOS RX: EN, DIS
UTILITIES VERSION: z.zz
RESTORE FACTORY?
SET PASSWORD
*
:
Figure 4.2
DDS CSU/DSU Menutree
The three-digit current and threshold values (###/###)
range from 000 to 900. An asterisk (*) to the left of these
values indicates that the current value has exceeded the
threshold value. Pressing SELECT on a displayed alarm
allows editing the threshold parameters for that alarm.
The values are shown as (sss/ttttt). The 15-
minute current value (sss) ranges from 000
to 900. The 24-hour total values (ttttt) range
from 00000 to 65535.
(Install mode only) If the DLCI TOTAL is greater than
000, a screen with the following format appears when
SELECT is pressed:
uuuu -> vvvv:www
xxxxms yyyykbps
uuuu - the local DLCI number
vvvv - ACT., IDLE, NEW, DEL., or REMOTE DLCI (if
discovered)
www - remote unit ID
xxxx - average delay (if discovered)
yyyy - committed information rate
*
This field establishes the unit password used for entering
the front panel interface. A password must be eight
characters. SCROLL increments the characters (09, A
Z, az). The cursor blinks over the character or digit to be
selected or modified. SELECT accepts the current value
and moves the cursor right. When the eighth character is
selected, a verification screen appears. Reenter the
password.
Monitor option only
§
This does not apply to frame relay alarms.
Default values are shown in bold.
1
The network configuration is automatically set when the
DTE Rate is set. For example, 56 Kbps DTE Rate sets the
network to DDS I and 64 Kbps DTE Rate sets the network
to DDS II CC 64K.