Verilink WANsuite 5650 (34-00314.E) Product Manual Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Verilink WANsuite 5650 (34-00314.E) Product Manual. Verilink WANsuite 5650 (34-00314.E) Product Manual User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 68
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
i
WANsuite
®
5650
Reference Manual
May 2002
34-00314.E
Przeglądanie stron 0
1 2 3 4 5 6 ... 67 68

Podsumowanie treści

Strona 1 - Reference Manual

iWANsuite® 5650Reference ManualMay 200234-00314.E

Strona 2 - WANsuite 5650

x WANsuite 5650Typographic ConventionsThe following table lists the graphic conventions used throughout this guide.Customer Service and Technical Supp

Strona 3 - Safety Certifications

Preface xiIf these toll-free numbers are not supported in your dialing area, you may call Verilink by direct dialing 1-256-327-2001.E-mailYou can requ

Strona 4

xii WANsuite 5650

Strona 5 - Table of Contents

About the WANsuite 5650 1-1CHAPTER1CHAPTER 1ABOUT THE WANSUITE 5650IntroductionThe telecommunications network service market is rapidly changing, wher

Strona 6 - Front Panel Interface

1-2 WANsuite 5650flexibility or utilization of the SHDSL pipe is achieved by allowing for the assignment of the individual timeslots to the desired en

Strona 7 - Specifications

About the WANsuite 5650 1-3Front Panel The front panel of the WANsuite 5650 has four user-activated input control buttons and nine LED status indicato

Strona 8

1-4 WANsuite 5650initiate/terminate tests and the corresponding LEDs indicate the status of tests on this port only.When on the G.703 port selection,

Strona 9 - About this Manual

About the WANsuite 5650 1-5Table 1.1LED Indicators LED LabelOffGreenAmberRedPOWERNo PowerPower applied to unitUnit in test mode.SHDSLMains Power OffTr

Strona 10 - Support from Verilink

1-6 WANsuite 5650Rear Panel ConnectionsThe rear panel of the WANsuite 5650 has five connectors. From left to right (as shown in Figure 1.2 below) thes

Strona 11 - Returning a Unit to Verilink

About the WANsuite 5650 1-7Supervisory PortThe SUPERVISORY PORT is a DB-9 female DCE connector configured for 8 bits, no parity, and 1 stop bit. Bit r

Strona 12

iiWANsuite 5650Copyright NoticeCopyright © 2002 Verilink Corporation. All rights reserved. No part of this publication may bereproduced, transmitted,

Strona 14 - Features Summary

Installation 2-1CHAPTER2CHAPTER 2INSTALLATIONThis chapter describes the contents of your WANsuite 5650 shipment and provides information on connecting

Strona 15 - NOTICE:

2-2 WANsuite 5650

Strona 16

VT100 Interface 3-1CHAPTER3CHAPTER 3VT100 INTERFACEIntroductionThis chapter describes the menus and options associated with the WANsuite 5650’s VT100

Strona 17 - Table 1.1

3-2 WANsuite 5650Cursor ControlsThe VT100 interface uses a blinking cursor to select various menus and then to select sub-menus and/or fields within t

Strona 18 - CAUTION:

VT100 Interface 3-3entry to be replaced by the new characters. To edit an existing entry rather than replace it, press the right arrow key to move the

Strona 19

3-4 WANsuite 5650System ScreenThe first option on the Main menu screen is the System screen (Figure 3.3). This screen lets you view and set specific i

Strona 20 - 1-8 WANsuite 5650

VT100 Interface 3-5Download App CodeUse the “Download App Code” field to upgrade the software in your WANsuite 5650 unit. The revision level for the s

Strona 21 - NSTALLATION

3-6 WANsuite 5650Figure 3.4Confirmation Screen NOTICE: Performing a “Maintenance Reset” or a “Save and Restart” will terminate communications with the

Strona 22 - 2-2 WANsuite 5650

VT100 Interface 3-7Interfaces ScreenThe Interfaces screen displays a list of all the unit’s available interfaces as shown in Figure 3.5. Figure 3.5Int

Strona 23 - NTERFACE

iii•When the power supply cord or plug is damaged or frayed.•If liquid has been spilled into the product.•If the product has been exposed to rain or w

Strona 24

3-8 WANsuite 5650Figure 3.6SHDSL ScreenUnit TypeSelects the unit type. TU-R represents a CPE terminal unit; TU-C represents a CO terminal unit. The T

Strona 25

VT100 Interface 3-9Expected RepeatersThis field is used to provision the number of repeaters in the selected span.Values:0, 1, 2, 3, 4, 5, 6, 7, 8 Def

Strona 26 - System Screen

3-10 WANsuite 5650Configuration Profiles ScreenSelecting the Configuration Profiles function field from the SHDSL screen will display the following sc

Strona 27 - Maintenance Reset--TDM

VT100 Interface 3-11Figure 3.8Configuration Details ScreenThis screen allows the user to view and change various parameters of the selected Configurat

Strona 28

3-12 WANsuite 5650Alarm Profiles ScreenSelecting the “Alarm Profiles” option on the SHDSL screen will display the following screen:Figure 3.9Alarm Pro

Strona 29 - SHDSL Screen

VT100 Interface 3-13Alarm Profile Details ScreenThe Alarm Profile Details screen (Figure 3.10) is accessed by moving the cursor over a profile name in

Strona 30

3-14 WANsuite 5650LOSWSThis field configures the threshold for the number of Loss of Sync Word (LOSW) Seconds within any given 15-minute performance d

Strona 31 - VT100 Interface 3-9

VT100 Interface 3-15Figure 3.12Span Endpoint Details Screen This screen provides details on the following span endpoint parameters: Vendor IDDisplays

Strona 32 - Configuration Profiles Screen

3-16 WANsuite 56503.13), Span Endpoint Performance Screen(s) (Figure 3.14), and the Alarm Profiles screen (Figure 3.9).Span Endpoint Maintenance Scree

Strona 33 - Configuration Details Screen

VT100 Interface 3-17Power SourceThis field indicates the DC power source being used by the associated unit.Restart EndpointThis field enables the mana

Strona 35 - Alarm Profile Details Screen

3-18 WANsuite 565015-Minute and 1-Day Intervals ScreensAlso included on the Span Endpoint Performance screen are options to view the span endpoint per

Strona 36 - Span Endpoints Screen

VT100 Interface 3-19CRC4 ModeUsed to disable or enable CRC-4 detection/generation towards the SHDSL network. When less than 32 timeslots are configure

Strona 37 - Span Endpoint Details Screen

3-20 WANsuite 5650The table provides error status and alarm threshold information for the following error parameters:ESSets the Errored Seconds (ES) t

Strona 38

VT100 Interface 3-21The G.703 configuration screen provides the user-selectable prompts described in the table below. PerformanceThe Performance promp

Strona 39 - Figure 3.14

3-22 WANsuite 5650Figure 3.17G.703 Performance 24-Hour Details Screen Select the “Performance 30 Day” prompt from the G.703 Performance 24 Hour screen

Strona 40 - G.703 Screen

VT100 Interface 3-23Figure 3.19G.703 Performance 30 Day Details Screen Serial ScreenThe Serial screens let you view and make changes to the unit’s Ser

Strona 41 - VT100 Interface 3-19

3-24 WANsuite 5650TypeThis parameter selects the type of interface (based on its electrical signal characteristics) used by the equipment connected to

Strona 42 - 3-20 WANsuite 5650

VT100 Interface 3-25clock that is also supplied to the DTE as Transmit Clock. The “External” option uses the external clock from the DTE. Values:Inter

Strona 43

3-26 WANsuite 5650DTR Alarm ControlLets you set DTR Alarm Control parameters.Values:Permanent On, DTE DrivenDefault:Permanent OnDTR Alarm StatusLets y

Strona 44 - Figure 3.18

VT100 Interface 3-27Supervisory ScreenThe Supervisory Configuration screen (Figure 3.21) displays the current speed of the Supervisory port interface.

Strona 45 - Serial Screen

vTable of ContentsPrefaceAbout this Manual ...

Strona 46

3-28 WANsuite 5650Service Table ScreenSelecting the “Services” option from the Main screen will display the Service Table screen shown below (Figure 3

Strona 47 - VT100 Interface 3-25

VT100 Interface 3-29Service Details ScreenFigure 3.23Service Details Screen This screen allows the user to select and change the service parameters li

Strona 48 - 3-26 WANsuite 5650

3-30 WANsuite 5650TDM Service Details ScreenSelecting the Channels function field from the SHDSL screen will display the TDM Service Details screen (F

Strona 49 - Supervisory Screen

VT100 Interface 3-31ApplicationsAccessed from the Main menu, The Applications screens describe diagnostics and traps for Layer 3 and above that do not

Strona 50 - Service Table Screen

3-32 WANsuite 5650Figure 3.26Test Details Screen Loop TypeDescribes the type of loop test (if any) performed on the selected interface. Values:No Test

Strona 51 - Service Details Screen

VT100 Interface 3-33The table shown in this screen lists each trap by its Index number, and displays the type of error captured by the trap (Trap Numb

Strona 53

Front Panel Interface 4-1CHAPTER4CHAPTER 4FRONT PANEL INTERFACEIntroductionThis chapter describes the LED status indicators and control buttons associ

Strona 54 - Trap Log Screen

4-2 WANsuite 5650SELECT button, the port’s corresponding LED will flash. The status of the LLOOP and RLOOP LEDs will be the summary of the test states

Strona 55 - VT100 Interface 3-33

Front Panel Interface 4-3LED IndicatorsThe table below describe the WANsuite 5650’s front panel LED indicators.NOTICE: The SHDSL, G.703, and Nx64 port

Strona 56 - 3-34 WANsuite 5650

viWANsuite 5650Chapter 3 VT100 InterfaceIntroduction ...

Strona 57

4-4 WANsuite 5650

Strona 58

A-1APPENDIXAAPPENDIX ASPECIFICATIONSData InterfacesSHDSL PortLine Rate: 200 kbps–2056 kbpsLine Framing:Aligned 2.048 Mbps (G.991.2 E7)Line Code:Trelli

Strona 59

A-2 WANsuite 5650Supervisory PortConnection:DB-9 femaleData Rates:(bps) 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 (default: 38400 bps)Protoc

Strona 60 - 4-4 WANsuite 5650

A-3Figure A.1G.SHDSL Loopback Diagrams WANsuite 5650Internal LogicNetworkPort(G.SHDSL)NetworkFramerG.703FramerG.703PortPortLogicNx64PortG.SHDSL Networ

Strona 61 - PECIFICATIONS

A-4 WANsuite 5650Figure A.2G.703 Loopback Diagrams WANsuite 5650Internal LogicNetworkPort(G.SHDSL)NetworkFramerG.703FramerG.703PortPortLogicNx64PortG.

Strona 62 - Supervisory Port

A-5Figure A.3Nx64 Loopback Diagrams WANsuite 5650NetworkPort(G.SHDSL)NetworkFramerInternal LogicG.703FramerG.703PortPortLogicNx64PortNx64 Network Side

Strona 63 - G.SHDSL Loopback Diagrams

A-6 WANsuite 5650Ordering InformationEach WANsuite 5650 unit is supplied with the following standard equipment: *Verilink Technical Support: toll-fre

Strona 64 - G.703 Loopback Diagrams

A-7Connector Pin AssignmentsSerial Interface Pin Assignments (DCE Mode)The table below displays Serial Interface Pin Assignments for the DCE Mode. Fun

Strona 65 - Nx64 Loopback Diagrams

A-8 WANsuite 5650SHDSL Interface Pin AssignmentsThe SHDSL interface is a standard eight-pin modular jack. The table below displays the pinout assignme

Strona 66 - Optional Equipment

viiAppendix A SpecificationsData Interfaces ...

Strona 68 - SUPERVISORY PORT

Preface ixCHAPTER 0PREFACEAbout this ManualThis reference guide for the Verilink WANsuite 5650 network termination unit (NTU) describes unit features

Komentarze do niniejszej Instrukcji

Brak uwag