Verilink 8100A (34-00237) Product Manual Instrukcja Użytkownika Strona 243

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 242
Troubleshooting and Diagnostics 7-5
SDSL Diagnostics
To perform SDSL diagnostics, type “S” on the Diagnostics menu. The IAD
displays the SDSL Diagnostics menu:
Figure 7.4
SDSL Diagnostics Menu
To perform a type of transmission, type the specific option. For option “P,
select the level to begin the transmission. Press any key to terminate the test.
Troubleshooting the IAD
This section provides information for troubleshooting symptoms associated
with the operation of the IAD. The table below describes symptoms and
probable causes, and suggests what action can be taken to correct the
problem.
Symptom Probable Cause Corrective Action
Power indicator is not lit
Power is not available
to the IAD
Ensure the power cord is
securely connected.
Ensure the power cord is
plugged into a live outlet.
Ensure the power switch is on.
If powered by an adapter,
ensure the correct adapter is
used.
LAN Link indicator is not lit
Incorrect Ethernet
connection
Ensure an Ethernet cable is
properly connected to the IAD
and its upstream connection.
No dial tone is present
Incorrect PVC/DLCI
set for voice channel
Verify these settings:
VPI: 0 to 255
VCI: 0 to 65535
DLCI: 16 to 1023
(default PVC 0/39; DLCI 33)
Przeglądanie stron 242
1 2 ... 238 239 240 241 242 243 244 245 246 247 248 ... 310 311

Komentarze do niniejszej Instrukcji

Brak uwag

Mr. Heater Bojler uživatelské příručky

Začínající na M

Klepnutím na abecedu níže přejděte na úplný seznam modelů začínajících tímto písmenem

Modely Typ Dokumentu
MH9B
Uživatelský manuál   Mr. Heater MH9B User Manual, 8 stránky