B-2 WANsuite 6450
rfc2013.mib for managing UDP implementations
rfc2096.mib for the display of CIDR multipath IP routes
rfc2493.mib provides textual conventions to be used by systems
supporting 15-minute based performance history counts
rfc2514.mib ATM Management MIB
rfc2515.mib ATM Management MIB
rfc2571.mib the SNMP Management Architecture MIB
rfc2863.mib describes generic objects for network interface sub-layers
(This MIB is an updated version of MIB-II's ifTable, and
incorporates the extensions defined in RFC 1229.)
rfc3276.mib MIB module for SHDSL
The WANsuite 6450 supports the following Enterprise-specific MIBs:
ds8200tc.mib textual conventions used by DS8200 MIB
ds8200v2.mib provides T1 configuration and statistics information
ipadatm.mib proprietary extensions to ATM Management MIBs
ipadv2.mib provides Frame Relay, PPP, and Service Aware
configuration and statistics
ipstart.mib MIB module for synchronous PPP
router.mib provides configuration of OSPF router
These MIB files may be found on the Verilink Documentation CD included
with the unit.
SNMP Trap Configuration
The WANsuite 6450 supports up to eight IP destinations for SNMP traps.
These may be configured either through the Web interface or through an
SNMP management application. For configuration of these destinations
through an SNMP management application, use a MIB browser to access the
table trapdest within ipadv2.mib and set the IP Addresses of the host
computer running the management application(s). Entering an IP Address of
0.0.0.0 will disable the entry.
Generic MIB Loading Instructions
The MIBs were written using the standard ASN.1 notation. Any standard SNMP
manager should be able to compile the MIBs. Although the exact procedure for
loading MIBs may vary from one platform to another, the following basic steps
are the same.
1 The SNMP manager has a directory for MIBs. Copy the files
ds8200tc.mib
, ds8200v2.mib, ipadv2.mib, ipstart.mib,
router.mib, and ipadatm.mib into this directory. The MIBs use a
DOS format; therefore, a DOS2UNIX command may have to be used for
UNIX workstations (typical directories are snmp_mibs for HP’s