Verilink WANsuite 7105 (34-00316.C) Product Manual Instrukcja Użytkownika Strona 230

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 255
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 229
4-96 WANsuite 7105
Tx High Utilization %
What the user considers Tx high utilization (expressed as a percentage) for
this service.
Values: 1100
Default: 75
Tx High Threshold
(sec)
Number of seconds Tx high utilization must be present before an alarm
reports.
Values: 0900
Default: 0 (Rx High Utilization Alarm Disabled)
Tx End of Day Low
Utilization %
What the user considers Tx low utilization at the end of the day for this
service.
Values: 0100
Default: 0 (Tx Low Utilization Alarm Disabled)
HDLC Status and Alarm Table
Each second, HDLC utilization detectors will report transmit and receive
utilization to update the statistics displayed in the table at the center of the
screen. This table also gives the status of the alarms related to HDLC utilization.
The user-activated prompts listed below are at the bottom of the HDLC
Utilization Monitor Details screen.
Figure 4.91
HDLC Monitor 24 Hour History Screen
Prompt Function
Clear Alarms Clears all HDLC Monitor alarms.
HDLC 24 Hour
History
Displays HDLC monitor history in 15-min buckets for the
past 24 hours (Figure 4.91).
HDLC 30 Day History Displays HDLC monitor history in 24-hr buckets for the past
30 days (Figure 4.92).
Przeglądanie stron 229
1 2 ... 225 226 227 228 229 230 231 232 233 234 235 ... 254 255

Komentarze do niniejszej Instrukcji