Web Server Interface 3-61
The Test Details screens provide the following user-activated buttons:
Trap Log Screen
The Trap Log screen (Figure 3.52) shows all traps that have been generated.
A trap is a mechanism that permits a device to send an alarm for certain
network events to an SNMP management station; in other words, traps are
notifications of triggered alarms.
The table shown in this screen lists each trap by its Index number, and
displays the type of error captured by the trap (Trap Number), the date and
time that the trap was stored (Time Stamp), its description, and its value.
To remove all trap information stored in memory, click the “Delete All
Traps” button.
Figure 3.52
Trap Log Screen
Top Talkers Screen
Clicking on the “Top Talkers” link in the navigation tree displays a screen
(Figure 3.53) where you can set the parameters for and initiate the generation
of a list of IP addresses ranked in terms of the number of frames and octets
they have transmitted during a specified reporting period. This report lets MIS
managers determine, based on IP addresses, who is generating the most traffic
on a WAN.
Button Function
Start Starts the specified BERT.
Stop Stops the currently running BERT.
Error Inject Injects a bit error.
Reset Errors Resets the current error count.
Loop Submit Sets the type of Loop test.