VT100 Interface 4-15
Figure 4.12
Alarm Profiles Screen
The Alarm Profiles screen displays the current status of endpoint alarms.
Information is displayed for the following alarm parameters:
Alarm Profiles
Unique index associated with this Endpoint Alarm profile.
The values are obtained from the alarm configuration profile referenced by
this object. The value of this object is the index of the referenced profile in
the Line Alarm Configuration Profile Table, or NULL (a string of length 0).
If the value is NULL, the endpoint uses the default Alarm Configuration
Profile for the associated span. The default value of this object is NULL.
Loop Attenuation
Indicates if the Loop attenuation threshold has been reached/exceeded for the
selected segment endpoint.
SNR Margin
Indicates if the Signal-to-Noise Ratio margin threshold has been reached/
exceeded for the selected segment endpoint.
ES
Indicates if the Errored Seconds threshold has been reached/exceeded for the
selected segment endpoint.
SES
Indicates if the Severely Errored Seconds threshold has been reached/
exceeded for the selected segment endpoint.
CRC
Indicates if the Cyclic Redundancy Check anomalies threshold has been
reached/exceeded for the selected segment endpoint.
LOSWS
Indicates if the Loss of Sync Word Second threshold has been reached/
exceeded for the selected segment endpoint.
UAS
Indicates if the Unavailable Seconds Threshold has been reached/exceeded for
the selected segment endpoint.