4-20 WANsuite 6x30
Figure 4.17
Span Endpoint Performance Screen
This screen displays information on the performance and error status of the
span endpoints. This information is provided in summary form for complete
totals and for the most recent 15 min period or most recent current day period.
Current state of the endpoint. This is a bit-map of possible conditions. The
various bit positions are as follows:
−
There no defects on the line.
−
Indicates enhanced Power Backoff.
−
Indicates a vendor-dependent detection of diagnostics or
−
Indicates vendor-dependent conditions that
interfere with span powering such as short and open circuits.
−
Indicates that the SNR margin has dropped below
32 (loopAttenuationAlarm)
−
Indicates that the loop attenuation has
dropped below the alarm threshold.
−
Indicates a forward LOSW alarm.
−
Endpoint failure during initialization due to paired
endpoint not able to support requested configuration.
256 (protocolInitFailure)
−
Endpoint failure during initialization due to
incompatible protocol used by the paired endpoint.
−
Endpoint failure during initialization due to no
activation sequence detected from paired endpoint.
−
A loopback is currently active at this Segment
Current Signal-to-Noise Ratio margin for this endpoint as reported in a Status
Current loop attenuation for this endpoint as reported in a Network or
Customer Side Performance Status message.